EM 100 G2, EM 300 G2, EM 500 G2
15/32 08/2004
3 RF module
RF module removal:
1. Loosen the lens screw (RF board fastening, see Exploded view, Pos. 12).
2. Remove both BNC socket screws from the back panel of the unit.
3. Remove the RF module (the connection to the mainboard via the 15-pin flat cable remains).
Re-establishing the ground connection between the RF module and the mainboard:
Create an interference-free connection between MH3 on the RF board and 801 on the
mainboard. To do this, solder a wire approx. 10cm long between MH3 and 801.
3.1 Operating voltage
(+5V
SW
)
+12V
DC
at the
DC socket
Multimeter, DC RF module
Component
side: L500
+4.9V to
+5.1V
3.2 Tuning voltage measurement
1. Open the center shielded compartment on the RF module.
2. On the track, solder a piece of wire approx. 2cm long to TP17 and one to TP4.
3. Guide the wires out of the receiver as measuring lines.
4. Set the C540 trimmer in the shielded compartment to precisely 2.4V; (use TP17 and TP4 for this).
3.2.1 Mid
range limit
See 3.1 Use TUNE to set the medi-
um receiving frequency.
RF module
Solder side:
TP 17
+2.3V to
+2.5V
Alignment via
RF module,
component
side C540
3.2.2 Lowest
range limit
See 3.1 Use TUNE to set the lowest
receiving frequency.
TP 17 +0.8V to
+2.0V
–
3.2.3 Uppermost
range limit
See 3.1 Use TUNE to set the highest
receiving frequency.
TP 17 +3.0V to
+4.2V
–
3.3 Oscillator
3.3.1 1. frequency
measurement
See 3.1 Use the "SET" and "DOWN"
buttons to switch to the
mid receiving frequency;
then spectrum analyzer
TP 1 LO1=
f
E
+241MHz
–
3.3.2 1. Oscillator level See 3.1 See 3.3.1 TP 102 /
TP 202
+4.3 V Measurement
takes place in-
directly via the
voltage at the
1st oscillator
3.3.3 2. frequency
measurement
See 3.1 See 3.3.1 TP 300 230.3MHz
± 11.5kHz
–
3.3.4 2. Oscillator level See 3.1 See 3.3.1 TP 300 -20dBm to
-35dBm
–
3.4 Sensitivity,
channel 1
Set the receiving fre-
quency on the RF signal
generator:
ANT I RF: 2, 5µV; devia-
tion: 24kHz mod: off
Center frequency;
Squelch at "0";
AF level measuring device
AF output Better than
52dB(A)
–
3.5 Sensitivity,
channel 2
See 3.4 at ANT II See 3.4 AF output Better than
52dB(A)
–
3.6 THD, channel 1 RF signal generator at
ANT I RF: 1mV; deviati-
on: 24kHz mod: 1kHz
– AF output < 0.9%,
typ. 0,3%
–
3.7 THD, channel 2 See 3.4 at ANT II – AF output < 0.9%,
typ. 0,3%
–
3.8 S/N max., channel 1 See 3.4 at ANT I
Mod: off
––Better than
110dB(A)
–
3.9 S/N
max, channel 2
See 3.4 at ANT II
Mod: off
––Better than
110dB(A)
–
3.10 AF output
voltage, tuner 1
See 3.1; Mod: on,
deviation: 48kHz
with AF meter TP 6 +540mV
eff
to
+555mV
eff
Alignment via
R360
3.11 AF output
voltage, tuner 2
See 3.1 Mod: on,
deviation: 48kHz
with AF meter TP 8 +540mV
eff
to
+555mV
eff
Alignment via
R460
Sequence Type of measure-
ment/adjustment
Signal input Settings Measuring
point/test
point
Required
value
Remarks