5 Test and alignment instructions
5.1 Measuring and test equipment
• 1 Spectrum analyzer up to at least 1.5GHz
• 1 RF signal generator
• 1 AF level measuring device
• 1 Oscilloscope
• 1 Multimeter
• 1 Laboratory power supply unit
5.2 Measuring set-up
+
230.00 MHz
DATA
RF signal generator
AF level measuring device
Oscilloscope
EM x00 G2
Laboratory
Spectrum analyzer
Multimeter
Other measuring equipment
DC IN
RF IN
AF OUT
power supply unit