Sennheiser SK 500 G3 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Satellit Sennheiser SK 500 G3 herunter. Sennheiser SK 500 G3 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Instruction manual

SK 500Instruction manual

Seite 2 - Contents

9Putting the bodypack transmitter into operation왘 Use one of the recommended Sennheiser microphonesor the optional CI 1 instrument cable (see “Accesso

Seite 3 - Important safety instructions

10Putting the bodypack transmitter into operationME 4왘 Use the microphone clip  to attach the microphone toclothing (e.g. tie, lapel).The ME 4 clip-o

Seite 4 - The SK 500 G3 bodypack

11Putting the bodypack transmitter into operationAttaching the bodypack transmitter to clothing You can use the belt clip  to attach the bodypack tra

Seite 5 - Areas of application

12Using the bodypack transmitterUsing the bodypack transmitterTo establish a transmission link, proceed as follows:1. Switch the receiver on (see the

Seite 6 - Delivery includes

13Using the bodypack transmitterTo switch the bodypack transmitter off:왘 If necessary, deactivate the lock mode (see page 13).To switch the bodypack t

Seite 7 - Product overview

14Using the bodypack transmitterThe lock mode icon  flashes prior to the lock mode beingactivated again.Muting the audio signal or deactivating the R

Seite 8 - Overview of the displays

15Using the bodypack transmitter왘 From the “Mute Mode” menu item, select the desiredsetting (see page 25). 왘 Exit the operating menu.왘 Slide the MUTE

Seite 9 - Putting the bodypack

16Using the bodypack transmitterSelecting a standard displayYou can also deactivate the RF signal on switch-on.For more information, refer to the chap

Seite 10

17Using the operating menuUsing the operating menu A special feature of the Sennheiser ew G3 series is theconsistent, intuitive menu structure of tran

Seite 11

18Using the operating menuOverview of the operating menu Display Function of the menu itemMain menu “Menu”Sensitivity Adjusts the sensitivity “AF”(see

Seite 12

1ContentsContentsImportant safety instructions ...2The SK 500 G3 bodypack transmitter...

Seite 13

19Using the operating menuWorking with the operating menu By way of example of the “Sensitivity” menu, this sectiondescribes how to use the operating

Seite 14

20Using the operating menuExiting a menu itemTo directly return to the current standard display:왘 Change to the “Exit” menu item.왘 Confirm your select

Seite 15 - RF signal

21Adjusting settings via the operating menuAdjusting settings via the operating menuThe main menu “Menu”Adjusting the input sensitivity – “Sensitivity

Seite 16

22Adjusting settings via the operating menuThe following figures are a guide to the best settings:Selecting the frequency bank and the channel manuall

Seite 17 - Selecting a standard display

23Adjusting settings via the operating menuEntering a name – “Name”Via the “Name” menu, you can enter a freely selectablename (e.g. the name of the pe

Seite 18 - Using the operating menu

24Adjusting settings via the operating menuThe extended menu “Advanced Menu”Setting transmission frequencies and frequency banks – “Tune”Via the “Tune

Seite 19

25Adjusting settings via the operating menu왘 Set the desired frequency bank.왘 Set the desired channel.왘 Set the desired frequency.Setting the mode for

Seite 20 - Sensitivity

26Adjusting settings via the operating menuEmulating guitar cables – “Cable Emulation”Via the “Cable Emulation” menu item, you can emulate4 different

Seite 21

27Adjusting settings via the operating menuAdjusting the contrast of the display panel – “LCD Contrast“You can adjust the contrast of the display pane

Seite 22 - The main menu “Menu”

28Synchronizing the bodypack transmitter with a receiverSynchronizing the bodypack transmitter with a receiverWhen synchronizing the bodypack transmit

Seite 23 - Frequency Preset

2Important safety instructionsImportant safety instructions• Read this instruction manual.• Keep this instruction manual. Always include thisinstructi

Seite 24

29Cleaning the bodypack transmitterCleaning the bodypack transmitter왘 Use a cloth to clean the bodypack transmitter from timeto time. 왘 Do not use any

Seite 25 - Advanced

30Recommendations and tipsRecommendations and tips... for the ME 2 and ME 4 clip-on microphones• To reduce level variations to a minimum when the user

Seite 26 - Standard

31If a problem occurs ...If a problem occurs ... If a problem occurs that is not listed in the above table or ifthe problem cannot be solved with the

Seite 27 - Pilot Tone

32Accessories and spare partsAccessories and spare partsThe following accessories are available from your specialistdealer:Cat. No. Product name and d

Seite 28

33SpecificationsSpecificationsRF characteristics Modulation wideband FMFrequency ranges 516–558, 566–608, 626–668, 734–776, 780–822, 823–865 MHz (A–E,

Seite 29 - Synchronizing the bodypack

34SpecificationsIn compliance with Approved byMicrophonesConnector assignment3.5 mm jack plug:Operating time typ. 8 hrsDimensions approx. 82 x 64 x 24

Seite 30 - Cleaning the bodypack

35SpecificationsPolar diagrams and frequency response curves of the microphonesPolar diagram ME 3 Polar diagram ME 4Frequency response curve ME 2Frequ

Seite 31 - Recommendations and tips

36Manufacturer DeclarationsManufacturer DeclarationsWarrantySennheiser electronic GmbH & Co. KG gives a warranty of24 months on this product.For t

Seite 32 - If a problem occurs

37Manufacturer Declarations• Reorient or relocate the receiving antenna.• Increase the separation between the equipment andreceiver.• Connect the equi

Seite 33 - Accessories and spare parts

38IndexIndexAAccupackcharging 8inserting 8Activating/deactivatinglock mode (Auto Lock) 23pilot tone 26Adjustingcable emulation 26contrast (LCD Contras

Seite 34 - Specifications

3The SK 500 G3 bodypack transmitterThe SK 500 G3 bodypack transmitterThis bodypack transmitter is part of the evolution wirelessseries generation 3 (e

Seite 35 - Connector assignment

39IndexFrequencypreset frequencies 3~ ranges 3selecting ~ presets 22setting the transmission ~ 24Frequency bankoverview 3selecting (Frequency Preset)

Seite 36 - 0° / 10 cm

40IndexSoftware Revision (displaying the software revision) 27Switching on/offbodypack transmitter 12Synchronizing (bodypack transmitter/receiver) 28T

Seite 37 - Manufacturer Declarations

Sennheiser electronic GmbH & Co. KGAm Labor 1, 30900 Wedemark, Germanywww.sennheiser.comPrinted in GermanyPubl. 01/09529695/A01

Seite 38

4The SK 500 G3 bodypack transmitterFor an overview of the frequency presets, please refer to thesupplied frequency information sheet. Updated versions

Seite 39

5Delivery includesDelivery includesThe packaging contains the following items:1 SK 500 G3 bodypack transmitter2 AA size batteries, 1.5 V1 instruction

Seite 40

6Product overviewProduct overviewOverview of the SK 500 G3 bodypack transmitter Microphone/instrument input (MIC/LINE),3.5 mm jack socket, lockable

Seite 41

7Product overviewOverview of the displaysAfter switch-on, the bodypack transmitter displays thestandard display “Frequency/Name”. For further illustra

Seite 42

8Putting the bodypack transmitter into operationPutting the bodypack transmitter into operationInserting the batteries/accupackFor powering the bodypa

Verwandte Modelle: 529695/A01

Kommentare zu diesen Handbüchern

Keine Kommentare